HOME > A-System

PARATEX Systems and Solutions

PARATEX Waterproofing Method System-A

A-1 A-3
A-2 A-4

Areas of application Protection layer System
Bathroom
Kitchen
Mortar, Tile (separate work) A-1
Balcony
Terrace
Passageway
External staircase
Eaves
Mortar, Tile (separate work) A-1
Colour coat (non-slip finish for light walkway) A-2
Colour coat S (non-slip finish for walkway) A-3
Top coat AU (smooth finish for light walkway) A-4
Crack, P-corn etc.
reinforce -waterproofing
------ A-1
Requirement for Preparatory work
  • Please apply steel trowel finish to the concrete substrate.
  • Make a right angle internal corner with good pass, and bevel an external angle with good pass.
  • Please consult us about materials other than reinforced concrete (e.g., autoclaved light-weight concrete).
  • *1 Trench pits on the plumbing pipe and double walls do not necessarily require protection.
  • *2 Colour Coat and Colour Coat S materials should be used after being diluted with water (within 5%). 1st 0.7kg/m2 / 2nd 0.5kg/m2